xemu/hw/xen
Chuck Zmudzinski 6bebd3f818 xen/pt: reserve PCI slot 2 for Intel igd-passthru
Intel specifies that the Intel IGD must occupy slot 2 on the PCI bus,
as noted in docs/igd-assign.txt in the Qemu source code.

Currently, when the xl toolstack is used to configure a Xen HVM guest with
Intel IGD passthrough to the guest with the Qemu upstream device model,
a Qemu emulated PCI device will occupy slot 2 and the Intel IGD will occupy
a different slot. This problem often prevents the guest from booting.

The only available workarounds are not good: Configure Xen HVM guests to
use the old and no longer maintained Qemu traditional device model
available from xenbits.xen.org which does reserve slot 2 for the Intel
IGD or use the "pc" machine type instead of the "xenfv" machine type and
add the xen platform device at slot 3 using a command line option
instead of patching qemu to fix the "xenfv" machine type directly. The
second workaround causes some degredation in startup performance such as
a longer boot time and reduced resolution of the grub menu that is
displayed on the monitor. This patch avoids that reduced startup
performance when using the Qemu upstream device model for Xen HVM guests
configured with the igd-passthru=on option.

To implement this feature in the Qemu upstream device model for Xen HVM
guests, introduce the following new functions, types, and macros:

* XEN_PT_DEVICE_CLASS declaration, based on the existing TYPE_XEN_PT_DEVICE
* XEN_PT_DEVICE_GET_CLASS macro helper function for XEN_PT_DEVICE_CLASS
* typedef XenPTQdevRealize function pointer
* XEN_PCI_IGD_SLOT_MASK, the value of slot_reserved_mask to reserve slot 2
* xen_igd_reserve_slot and xen_igd_clear_slot functions

Michael Tsirkin:
* Introduce XEN_PCI_IGD_DOMAIN, XEN_PCI_IGD_BUS, XEN_PCI_IGD_DEV, and
  XEN_PCI_IGD_FN - use them to compute the value of XEN_PCI_IGD_SLOT_MASK

The new xen_igd_reserve_slot function uses the existing slot_reserved_mask
member of PCIBus to reserve PCI slot 2 for Xen HVM guests configured using
the xl toolstack with the gfx_passthru option enabled, which sets the
igd-passthru=on option to Qemu for the Xen HVM machine type.

The new xen_igd_reserve_slot function also needs to be implemented in
hw/xen/xen_pt_stub.c to prevent FTBFS during the link stage for the case
when Qemu is configured with --enable-xen and --disable-xen-pci-passthrough,
in which case it does nothing.

The new xen_igd_clear_slot function overrides qdev->realize of the parent
PCI device class to enable the Intel IGD to occupy slot 2 on the PCI bus
since slot 2 was reserved by xen_igd_reserve_slot when the PCI bus was
created in hw/i386/pc_piix.c for the case when igd-passthru=on.

Move the call to xen_host_pci_device_get, and the associated error
handling, from xen_pt_realize to the new xen_igd_clear_slot function to
initialize the device class and vendor values which enables the checks for
the Intel IGD to succeed. The verification that the host device is an
Intel IGD to be passed through is done by checking the domain, bus, slot,
and function values as well as by checking that gfx_passthru is enabled,
the device class is VGA, and the device vendor in Intel.

Signed-off-by: Chuck Zmudzinski <brchuckz@aol.com>
Reviewed-by: Michael S. Tsirkin <mst@redhat.com>
Reviewed-by: Stefano Stabellini <sstabellini@kernel.org>
Message-Id: <b1b4a21fe9a600b1322742dda55a40e9961daa57.1674346505.git.brchuckz@aol.com>
Signed-off-by: Anthony PERARD <anthony.perard@citrix.com>
(cherry picked from commit 4f67543bb8c5b031c2ad3785c1a2f3c255d72b25)
Signed-off-by: Michael Tokarev <mjt@tls.msk.ru>
2023-05-18 21:09:59 +03:00
..
meson.build xen/pt: fix syntax error that causes FTBFS in some configurations 2022-11-05 20:35:45 +01:00
trace-events docs: fix references to docs/devel/tracing.rst 2021-06-02 06:51:09 +02:00
trace.h trace: switch position of headers to what Meson requires 2020-08-21 06:18:24 -04:00
xen-backend.c xen-bus: reduce scope of backend watch 2020-10-19 16:32:41 +01:00
xen-bus-helper.c hw: Do not include hw/sysbus.h if it is not necessary 2021-05-02 17:24:50 +02:00
xen-bus.c aio-posix: split poll check from ready handler 2022-01-12 17:09:39 +00:00
xen-host-pci-device.c xen: Use ERRP_GUARD() 2020-07-10 15:18:09 +02:00
xen-host-pci-device.h Clean up decorations and whitespace around header guards 2016-07-12 16:20:46 +02:00
xen-legacy-backend.c softmmu/qdev-monitor: add error handling in qdev_set_id 2021-10-15 16:08:46 +02:00
xen_devconfig.c Include sysemu/sysemu.h a lot less 2019-08-16 13:31:53 +02:00
xen_pt.c xen/pt: reserve PCI slot 2 for Intel igd-passthru 2023-05-18 21:09:59 +03:00
xen_pt.h xen/pt: reserve PCI slot 2 for Intel igd-passthru 2023-05-18 21:09:59 +03:00
xen_pt_config_init.c hw/xen: set pci Atomic Ops requests for passthrough device 2022-09-27 14:23:23 +01:00
xen_pt_graphics.c hw/xen/xen_pt: Resolve igd_passthrough_isa_bridge_create() indirection 2022-05-12 12:07:06 +02:00
xen_pt_load_rom.c pci: add romsize property 2021-02-05 08:52:58 -05:00
xen_pt_msi.c hw/xen: Don't use '#' flag of printf format 2020-12-13 17:02:42 +01:00
xen_pt_stub.c xen/pt: reserve PCI slot 2 for Intel igd-passthru 2023-05-18 21:09:59 +03:00
xen_pvdev.c util/log: Remove qemu_log_flush 2022-04-20 10:51:11 -07:00